Enhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator

dc.contributor.advisorLongoria, Raul G.
dc.contributor.committeeMemberChen, Dongmei
dc.contributor.committeeMemberWang, Junmin
dc.contributor.committeeMemberRausch, Manuel
dc.creatorRapp, Ethan Stewart
dc.creator.orcid0000-0002-2596-4522
dc.date.accessioned2021-09-14T23:06:07Z
dc.date.available2021-09-14T23:06:07Z
dc.date.created2021-08
dc.date.issued2021-08-10
dc.date.submittedAugust 2021
dc.date.updated2021-09-14T23:06:07Z
dc.description.abstractAs the number of patients experiencing severe heart failure increases, so too does the need and use of implantable mechanical circulatory support devices, such as ventricular assist devices (VADs) and total artificial hearts (TAHs), for patient treatment. These devices assist the failing heart by taking over the blood pumping process either partially or completely and must be properly vetted and verified for human use by undergoing many years of testing, both using in vitro benchtop and in vivo animal testing. To expedite the laboratory testing process, hardware-in-the-loop (HIL) systems called mock circulation loops (MCLs) have been developed that can test assist devices within a mechanical realization of the human cardiovascular environment. This research focuses on the evaluation of nominal and enhanced VAD function using a hybrid mock circulation loop (hMCL) as a HIL test platform. The research can be split into three major aims: (1) hMCL construction and performance characterization for nominal VAD testing, (2) hMCL based evaluation of enhanced VAD onboard estimation algorithms, (3) Method for HIL implementation of arrhythmic and VAD induced cardiac events in hMCL. Regarding Aim 1, test results of the current hMCL design show that root-mean-square error between simulated and realized physiological pressures across a range of VAD flowrates can be maintained within 1.5-3.5 [mmHg]. The hMCL is able to simulate different levels of patient cardiovascular health and basic sensitivity tests indicate responsiveness to changes in the simulated model parameters; a necessary requirement to accomplish Aim 2. Completed work towards Aim 2 involves evaluating the onboard sensing algorithms being developed on VADs using sensor-based estimation of systemic vascular resistance (SVR) as an example. Preliminary experiments using the hMCL showed that SVR value estimates were accurate within 1.3% and 0.7% compared to the set numerical model values for tests run on continuous and pulsatile flow VADs, respectively. Lastly, methods for incorporating arrhythmic cardiac events and valvular stenosis have been presented towards Aim 3. Preliminary results show less than 2% and 4% mean percent error between aortic and left ventricular pressure tracking, respectively, as well as good agreement between referenced and measured frequency content.
dc.description.departmentMechanical Engineering
dc.format.mimetypeapplication/pdf
dc.identifier.urihttps://hdl.handle.net/2152/87740
dc.identifier.urihttp://dx.doi.org/10.26153/tsw/14684
dc.language.isoen
dc.subjectArrhythmia
dc.subjectCardiovascular disorders
dc.subjectElectrocardiography
dc.subjectHeart excitation
dc.subjectHybrid mock circulation loop
dc.subjectMedical control systems
dc.subjectPatient treatment
dc.subjectPhysiological models
dc.subjectSystemic vascular resistance
dc.subjectVAD Estimation
dc.titleEnhanced implantable device evaluation using a hardware-in-the-loop circulatory simulator
dc.typeThesis
dc.type.materialtext
thesis.degree.departmentMechanical Engineering
thesis.degree.disciplineMechanical Engineering
thesis.degree.grantorThe University of Texas at Austin
thesis.degree.levelDoctoral
thesis.degree.nameDoctor of Philosophy

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RAPP-DISSERTATION-2021.pdf
Size:
8.02 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 2 of 2
No Thumbnail Available
Name:
PROQUEST_LICENSE.txt
Size:
4.45 KB
Format:
Plain Text
Description:
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.84 KB
Format:
Plain Text
Description: