Design and analysis of an electronically switchable ion exchange system

dc.contributor.advisorKatz, Lynn Ellenen
dc.contributor.advisorHolcombe, James A.en
dc.creatorKannappan, Ramakrishnanen
dc.date.accessioned2010-06-21T20:14:37Zen
dc.date.available2010-06-21T20:14:37Zen
dc.date.issued2009-12en
dc.descriptiontexten
dc.description.abstractMetal contamination is a considerable environmental problem because metals are persistent contaminants. Ion exchange is one of the most commonly used treatment options for trace metal removal. This research develops and evaluates a redox active modified ion exchange system that has the potential to reduce the ionic strength of ion exchange regeneration streams. Poly-L-cysteine (PLC) was selected as the redox active, adsorbing functional group on the surface of a reticulated vitreous carbon (RVC) electrode. PLC is an excellent soft acid metal chelator and is unique in that its thiol groups can form disulfide bonds with each other. The reduction of available thiols changes the metal binding capacity of the peptide since the thiol is the primary binding group. RVC provides a macroporous conductive monolithic resin to support the peptide. An experimental apparatus was designed to study the properties of this system and estimate performance. Distinct oxidized and reduced states of PLC on the surface of the RVC were confirmed by changes in metal binding characteristics. Adsorption edges showed a sharper pH dependence for the reduced electrode compared to the oxidized electrode from pH 3-7. Adsorption isotherms performed at pH 7 showed increased capacity for the reduced electrode. The change was reversible by chemical and electrical reduction. This difference was confirmed at the molecular level with Cd- EXAFS of oxidized and reduced electrodes. A greater degree of cadmium-sulfur coordination was observed on the reduced electrode and a greater cadmium-oxygen coordination was apparant on an oxidized electrode. A multidentate adsorption model was developed to model the pH dependent behavior of cadmium adsorption on the PLC-RVC surface. Nickel adsorption showed increased adsorption in the oxidized state. The most likely explanation is increased carboxylate complexation. The electronically switchable ion exchange system (ESIE) provides a framework for modifying traditional ion exchange processes. The system has 5 to 10 times less specifc capacity than current ion exchange systems, but uses solutions 10-100 times lower in ionic strength for regeneration. Further studies on the effect of ionic strength on adsorption and current usage are necessary to compare the cost of the ESIE process to traditional ion exchange.en
dc.description.departmentCivil, Architectural, and Environmental Engineeringen
dc.format.mediumelectronicen
dc.identifier.urihttp://hdl.handle.net/2152/7834en
dc.language.isoengen
dc.rightsCopyright is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.en
dc.subjectMetal contaminationen
dc.subjectIon exchangeen
dc.subjectPoly-L-cysteineen
dc.subjectReticulated vitreous carbonen
dc.subjectRedox active modified ion exchangeen
dc.subjectMetal bindingen
dc.subjectAdsorptionen
dc.titleDesign and analysis of an electronically switchable ion exchange systemen
thesis.degree.departmentCivil, Architectural, and Environmental Engineeringen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorThe University of Texas at Austinen
thesis.degree.levelDoctoralen
thesis.degree.nameDoctor of Philosophyen

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
kannappanr34267.pdf
Size:
1.13 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.75 KB
Format:
Item-specific license agreed upon to submission
Description: