Extending the depth limit of multiphoton microscopy for in vivo brain imaging

dc.contributor.advisorDunn, Andrew Kenneth, 1970-
dc.contributor.committeeMemberYeh, Hsin-Chih "Tim"
dc.creatorMiller, David Roger
dc.date.accessioned2016-10-19T15:52:24Z
dc.date.available2016-10-19T15:52:24Z
dc.date.issued2016-08
dc.date.submittedAugust 2016
dc.date.updated2016-10-19T15:52:24Z
dc.description.abstractThe benefit of high-resolution imaging provided by optical microscopy has resulted in many discoveries in both biology and neuroscience. Two-photon fluorescence microscopy (2PM) is widely used for in vivo brain imaging to visualize cerebral vasculature and neuronal physiology. Conventional 2PM using titanium-doped sapphire oscillators is typically limited to imaging depths less than 600 um due to their short excitation wavelengths (700 -1,000 nm) and low pulse energy (~10 nJ). The ideal approach for deep imaging is to use both longer wavelengths to reduce the effects of scattering by heterogeneous brain tissue and higher energy pulses such that more photons reach the excitation volume at deeper tissue depths. I perform high-resolution, non-invasive, in vivo deep-tissue imaging of the mouse neocortex using multiphoton microscopy with a high repetition rate optical parametric amplifier (OPA). The OPA outputs 400 nJ pulse energies and is tunable from 1,100 to 1,400 nm. The tunability of the OPA is an advantage over other high-pulse-energy lasers because the OPA wavelength can be matched to the peak absorption of the target fluorophore, enabling the excitation of numerous different fluorophores. I demonstrate an imaging depth of 1,200 um in vasculature labeled with Texas Red and 1,160 um in neurons labeled with tdTomato, and perform line scans as deep as 1200 um to measure the blood flow speed in a single capillary. I also demonstrate deep-tissue imaging using Indocyanine Green (ICG), which is FDA approved and a promising route to translate multiphoton microscopy to human applications.
dc.description.departmentBiomedical Engineering
dc.format.mimetypeapplication/pdf
dc.identifierdoi:10.15781/T2HM52M54
dc.identifier.urihttp://hdl.handle.net/2152/41746
dc.language.isoen
dc.subjectMultiphoton microscopy
dc.subjectOptical parametric amplifier
dc.subjectDeep-tissue brain imaging
dc.titleExtending the depth limit of multiphoton microscopy for in vivo brain imaging
dc.typeThesis
dc.type.materialtext
thesis.degree.departmentBiomedical Engineering
thesis.degree.disciplineBiomedical engineering
thesis.degree.grantorThe University of Texas at Austin
thesis.degree.levelMasters
thesis.degree.nameMaster of Science in Engineering

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
MILLER-THESIS-2016.pdf
Size:
2.18 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
LICENSE.txt
Size:
1.84 KB
Format:
Plain Text
Description: