Reduced-Order Dynamic Model of Permanent Magnet and HTSC Interaction in an Axisymmetric Frame
dc.creator | Hearn, C. S. | en |
dc.creator | Pratap, S. B. | en |
dc.creator | Chen, D. | en |
dc.creator | Longoria, R. G. | en |
dc.date.accessioned | 2015-09-04T16:06:18Z | en |
dc.date.available | 2015-09-04T16:06:18Z | en |
dc.date.issued | 2014-08 | en |
dc.description.abstract | This paper presents a reduced order model for a permanent magnet (PM) and high-temperature superconductor (HTSC) in an axisymmetric frame. This model is formulated as a bond-graph to aid integration into system models for applications such as lift bearings, where the nonlinear force–displacement interactions are important for stability analysis and control design. The reduced-order model is based on the mechanical and electromagnetic interaction between a PM and bulk HTSC. Performance of the proposed reduced-order model is compared to finite element method (FEM) analysis and experimental tests to confirm the static and transient performance. | en |
dc.description.department | Center for Electromechanics | en |
dc.identifier | PR_570 | en |
dc.identifier.citation | C. S. Hearn, S. B. Pratap, D. Chen, R. G. Longoria, “Reduced-Order Dynamic Model of Permanent Magnet and HTSC Interaction in an Axisymmetric Frame”, IEEE Transactions on Mechatronics, vol. PP, no. 99, pp. 1-8, Aug. 2013. | en |
dc.identifier.uri | http://hdl.handle.net/2152/30803 | en |
dc.language.iso | en | en |
dc.publisher | IEEE | en |
dc.relation.ispartof | CEM Publications | en |
dc.rights.restriction | open | en |
dc.subject | Rotating Machine | en |
dc.subject | High-temperature superconductors (HTSCs) | en |
dc.subject | magnetic levitation | en |
dc.subject | modeling | en |
dc.subject | simulation. | en |
dc.title | Reduced-Order Dynamic Model of Permanent Magnet and HTSC Interaction in an Axisymmetric Frame | en |
dc.type | article | en |
Access full-text files
Original bundle
1 - 1 of 1