Comparison of the Nature of Torque Production in Reluctance and Induction Motors

Access full-text files

Date

1990-06

Authors

Hsu, J. S.
Liou, S. P.
Woodson, H. H.

Journal Title

Journal ISSN

Volume Title

Publisher

IEEE

Abstract

The nature of torque production is different in reluctance and inductance motors. One significant difference occurs in a reluctance motor that has nonsalient stator punching and a salient motor. When the flux per pole is small in such a motor, the torque can still be high, as long as the rate of energy change with respect to the rotor angular displacement at the rotor pole fronts and pole ends is high. A theoretical foundation to improve the torque capability of reluctance motors is provided. Effects of saturation and stray-load loss are also studied. Experimental results show agreement with theoretical conclusions

Description

LCSH Subject Headings

Citation

J.S. Hsu, S.P. Liou, and H.H. Woodson, “Comparison of the nature of torque production in reluctance and induction motors,” IEEE Transactions on Energy Conversion, vol. 5, no. 1, March 1990, pp. 140-109.