The nature of torque production is different in reluctance and inductance motors. One significant difference occurs in a reluctance motor that has nonsalient stator punching and a salient motor. When the flux per pole is small in such a motor, the torque can still be high, as long as the rate of energy change with respect to the rotor angular displacement at the rotor pole fronts and pole ends is high. A theoretical foundation to improve the torque capability of reluctance motors is provided. Effects of saturation and stray-load loss are also studied. Experimental results show agreement with theoretical conclusions