Browsing by Subject "Metamorphic core complex"
Now showing 1 - 3 of 3
- Results Per Page
- Sort Options
Item Investigating the effect of high-angle normal faulting on unroofing histories of the Santa Catalina-Rincon and Harcuvar metamorphic core complexes, using apatite fission-track and apatite and zircon (U-Th)/He thermochronometry(2013-12) Sanguinito, Sean Michael; Ketcham, Richard Alan, 1965-The formation and evolution of metamorphic core complexes has been widely studied using low temperature thermochronometry methods. Interpretation of these data has historically occurred through the lens of the traditional slip rate method which provides a singular rate that unroofing occurs at temporally as well as spatially, and assumes unroofing is dominated by motion on a single master detachment fault. Recently, several new studies have utilized (U-Th)/He ages with a higher spatial density and greater nominal precision to suggest a late-stage rapid increase in the rate of unroofing. This analysis is based on the traditional slip rate method interpretation of broad regions of core complexes that display little to no change in age along the slip direction. An alternative interpretation is presented that instead of a change in slip rate, there may have been a change in the style of unroofing, specifically caused by the transfer of displacement from low-angle detachment faulting to high-angle normal faults. Apatite fission-track (AFT), and apatite and zircon (U-Th)/He (AHe and ZHe) analyses were applied to samples from the Santa Catalina-Rincon (n=8 AHe, and n=9 ZHe) and Harcuvar (n=12 AFT, n=16 AHe, and n=17 ZHe) metamorphic core complexes in an attempt to resolve the possible thermal effects of high-angle normal faulting on core complex formation. Samples from the Harcuvars were taken along a transect parallel to slip direction with some samples specifically targeting high-angle normal fault locations. The AFT data collected here has the advantage of improved analysis and modeling techniques. Also, more than an order of magnitude more data were collected and analyzed than any previous studies within the Harcuvars. The AFT ages include a trend from ~22 Ma in the southwest to ~14 Ma in the northeast and provide a traditional slip rate of 7.1 mm/yr, similar to previous work. However, two major high-angle, detachment-parallel normal faults were identified, and hanging-wall samples are ~3 m.y. older than the footwalls, indicating high-angle normal faults rearranged the surface expression of the distribution of thermochronometer ages to some extent. AHe ages range from 8.1 Ma to 18.4 Ma but in general decrease with increasing distance in the slip direction. ZHe ages generally range between 13.6 Ma and 17.4 Ma. A series of unexpectedly young AFT ages (10-11 Ma), given by three complete samples and distinct population modes in others, suggest that some parts of the range underwent a later-stage unroofing event possibly caused by high-angle faulting. Confined fission-track length distributions were measured for Harcuvar samples and modeled using the modeling software HeFTy to infer thermal histories and calculate local cooling rates. These imply a component of steady cooling in some parts of the range, evidence of a different departure from a single-detachment dominated model.Item Kinematic and geometric evolution of the Buckskin-Rawhide metamorphic core complex, west-central Arizona(2011-12) Singleton, John Selwyn; Mosher, Sharon, 1951-Reconstructing the structural evolution of metamorphic core complexes is critical to understanding how large-magnitude extension is accommodated in the middle to upper crust. This dissertation focuses on the Miocene geometric and kinematic evolution of the Buckskin-Rawhide metamorphic core complex in west-central Arizona, addressing controversial topics including the geometric development of mid-crustal shear zones, the formation of detachment fault corrugations, and the transition from detachment faulting to more distributed deformation. Detailed microstructural data from mylonites in the lower plate of the Buckskin-Rawhide detachment fault indicate that early Miocene mylonitization was characterized by consistent top-NE-directed shear and ~450-500°C deformation temperatures that varied by [less-than or equal to]50°C across a distance of ~35 km in the extension direction. The relatively uniform deformation conditions and strain recorded in mylonitized ~22-21 Ma granitoids are incompatible with models in which the lower plate shear zone represents the down-dip continuation of a detachment fault. Instead, lower plate mylonites initiated as a subhorizontal shear zone that was captured and rapidly exhumed by a moderately to gently dipping detachment fault system. Structural data and geologic mapping demonstrate that the prominent NE-trending Buckskin-Rawhide detachment fault corrugations are folds produced by extension-perpendicular (NW-SE) shortening during core complex extension. Dominant NE-directed slip on the detachment fault was progressively overprinted by NW- and SE-directed slip associated with corrugation folding. Orientation patterns of upper plate bedding across the corrugations are compatible with folding about a NE-trending axis. Extension-perpendicular shortening in the lower plate is recorded by synmylonitic constriction and folding. Upright m-scale and km-scale lower plate folds parallel the detachment fault corrugations and developed primarily by postmylonitic flexural slip that was coeval with detachment faulting. The total amount of NW-SE shortening across the lower plate is ~10%, but the amount of NW-SE shortening recorded by the younger detachment fault is only ~1%. The relatively late-stage development of corrugations in the Buckskin-Rawhide metamorphic core complex suggests that extension-perpendicular shortening was primarily driven by a reduction of vertical stresses through crustal thinning and tectonic denudation. Brittle fault data document the transition from large-magnitude, NE-directed extension to distributed E-W extension and right-lateral faulting. Following exhumation to brittle conditions, lower plate mylonites were extended up to ~20-30% by NE-dipping, syndetachment normal faults. Towards the end of detachment faulting, the extension direction rotated clockwise, and some portions of the Buckskin detachment fault record a transition from dominant top-NE slip to ENE- and E-directed slip. After detachment faulting ceased, E-W extension was accommodated primarily by steeply NE-dipping, right-lateral and oblique right-lateral-normal faults. The cumulative amount of right-lateral shear across the core complex is probably 7-9 km, which is the amount needed to restore the topographic trend of lower plate corrugations into alignment with the dominant extension direction. Postdetachment right-lateral/transtensional faulting across the Buckskin-Rawhide metamorphic core complex reflects the increasing influence of the Pacific-North American transform plate boundary towards the end of the middle Miocene.Item Tectonic evolution of Aegean metamorphic core complexes, Andros and Tinos Islands, Greece(2014-05) Shin, Timothy Andrew; Stockli, Daniel F.; Catlos, Elizabeth J., 1971-The Aegean is a classic setting for studying exhumation of high-pressure (HP) metamorphic rocks. Two end-member models are proposed to explain the uplift of these rocks: core-complex style extension along low-angle normal faults and extrusion-wedge uplift. Extrusion-wedge underplating is the mechanism that exhumed HP rocks on Evia whereas Tinos hosts several detachments varying in age from 30-9 Ma. Andros, situated between them, may be the geological manifestation of the interplay of these processes and provides an opportunity to test these models. Detachments on NW Tinos and on Andros and the enigmatic low-angle Makrotantalon Unit contact on Andros were insufficiently dated prior to this study. Geo- and thermochronometrycombined with structural observations from sampling transects in the transport direction from (1) lower plate Cycladic Blueschist Unit on Andros and Tinos, (2) middle plate Makrotantalon Unit on Andros, and (3) hanging wall Upper Unit address these issues. Maximum depositional ages from detrital zircon U-Pb geochronometry and structures reveal Paleocene-Eocene syn-HP metamorphism thrusting resulted in an inversed-age relationship between the Permian Makrotantalon Unit and the underlying Triassic-Eocene Cycladic Blueschist Unit on Andros. The Makrotantalon Unit has an internal inversed stratigraphy whereas the Cycladic Blueschist Unit on Andros and Tinos appear stratigraphically intact. Structures and zircon and apatite (U-Th)/He ages in transects from NW Tinos (~12-8 Ma) and central Andros Cycladic Blueschist Unit (~13-7 Ma) indicate rapid cooling due to exhumation associated with the Livada Detachment. Older cooling ages (~16-10 Ma) and structures in the Makrotantalon Unit indicate later brittle strain localization on the Makrotantalon Thrust contact is accommodated by rheologically weaker serpentinites and calc-schists, resulting in slivering of the footwall under the Livada Detachment on Andros. Estimated mean cooling slip rates of the Livada Detachment on Andros of ~3.8 (+1.2/-1.3) km/Myr and 2.1 (+0.2/-0.2) km/Myr on NW Tinos resulted in minimum vertical exhumations of 15 km and 4 km, respectively. The NCDS here accommodated ~12-25% of 60 km of HP-rock exhumation from ~30-7 Ma. We present a tectonic model to elucidate the evolution of the Makrotantalon Unit and the magnitude, temporal, and spatial variability of exhumation via detachments on these islands.