An Ethical Analysis of the MGPI Toxic Chemical Release in Atchison, Kansas 2016

dc.creatorLim, Arianna
dc.creatorDean, Christopher
dc.date.accessioned2021-04-21T15:49:52Z
dc.date.available2021-04-21T15:49:52Z
dc.date.issued2020
dc.descriptionThis paper examines MGPI’s unethical actions that led to the formation of a toxic chlorine gas plume on October 16, 2016 at their plant in Atchison, Kansas. Two parties were involved in the accident: MGPI and Harcros Chemicals. MGPI distills alcohols and Harcros Chemicals delivers specialty chemicals. While making a routine delivery to the MGPI plant, a Harcros truck driver inserted a hose containing sulfuric acid into the sodium hypochlorite fill line, leading to a reaction farther up the line in the sodium hypochlorite tank. This reaction led to six hospitalizations and necessitated medical attention for 140 others. Although the toxic gas release may seem most directly a result of the Harcros chemical driver filling the wrong fill line, it is actually the result of MGPI’s failure to follow professional ethical tenets. We apply Chevron Phillips’ tenets of operation as a guideline for what tenets MGPI ought to have followed because following these tenets has aided Chevron Phillips’ in becoming one of the safest companies in the chemical industry. Therefore, by violating many of Chevron Phillips’ tenets of operation in their safety procedures, MGPI acted unsafely and unethically. Since the incident, MGPI has made efforts to prevent similar incidents from occurring and to take care of its local community. Delivery companies and chemical plants can learn from this accident to reevaluate their own systems to address possible dormant chemical safety threats and prevent similar accidents from occurring.en_US
dc.description.departmentChemical Engineeringen_US
dc.description.sponsorshipRandall, D’arcy
dc.identifier.urihttps://hdl.handle.net/2152/85396
dc.identifier.urihttp://dx.doi.org/10.26153/tsw/12360
dc.language.isoengen_US
dc.relation.ispartofStudent Worksen_US
dc.rights.restrictionOpenen_US
dc.subjectWriting Flag Awarden_US
dc.subjectsafetyen_US
dc.subjectEthics reporten_US
dc.subjectengineering case studyen_US
dc.subjectCHE 333Ten_US
dc.titleAn Ethical Analysis of the MGPI Toxic Chemical Release in Atchison, Kansas 2016en_US
dc.typeArticleen_US

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
LimUGS Writing Awards - Dean and Lim, MGPI Ethics Report.pdf
Size:
733.25 KB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.64 KB
Format:
Item-specific license agreed upon to submission
Description: