Automated multi-radionuclide separation and analysis with combined detection capability

dc.contributor.advisorLandsberger, Sheldonen
dc.creatorPlionis, Alexander Asteriosen
dc.date.accessioned2008-08-29T00:00:23Zen
dc.date.available2008-08-29T00:00:23Zen
dc.date.issued2007-12en
dc.description.abstractThe radiological dispersal device (RDD) is a weapon of great concern to those agencies responsible for protecting the public from the modern age of terrorism. In order to effectively respond to an RDD event, these agencies need to possess the capability to rapidly identify the radiological agents involved in the incident and assess the uptake of each individual victim. Since medical treatment for internal radiation poisoning is radionuclide-specific, it is critical to identify and quantify the radiological uptake of each individual victim. This dissertation describes the development of automated analytical components that could be used to determine and quantify multiple radionuclides in human urine bioassays. This is accomplished through the use of extraction chromatography that is plumbed in-line with one of a variety of detection instruments. Flow scintillation analysis is used for ⁹⁰Sr and ²¹⁰Po determination, flow gamma analysis is used assess ⁶⁰Co and ¹³⁷Cs, and inductively coupled plasma mass spectrometry is used to determine actinides. Detection limits for these analytes were determined for the appropriate technique and related to their implications for health physics.en
dc.description.departmentMechanical Engineeringen
dc.format.mediumelectronicen
dc.identifier.oclc207087598en
dc.identifier.urihttp://hdl.handle.net/2152/3636en
dc.language.isoengen
dc.rightsCopyright © is held by the author. Presentation of this material on the Libraries' web site by University Libraries, The University of Texas at Austin was made possible under a limited license grant from the author who has retained all copyrights in the works.en
dc.subject.lcshRadioisotopes--Analysisen
dc.subject.lcshScintillation countersen
dc.subject.lcshGamma ray detectorsen
dc.subject.lcshInductively coupled plasma mass spectrometryen
dc.titleAutomated multi-radionuclide separation and analysis with combined detection capabilityen
dc.type.genreThesisen
thesis.degree.departmentMechanical Engineeringen
thesis.degree.disciplineMechanical Engineering.en
thesis.degree.grantorThe University of Texas at Austinen
thesis.degree.levelDoctoralen
thesis.degree.nameDoctor of Philosophyen

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
plionisa62882.pdf
Size:
2.04 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.65 KB
Format:
Plain Text
Description: