The equivalent T circuit of the induction motor: its nonuniqueness and use to the magnetic field analyst

dc.creatorDavey, K.R.en
dc.date.accessioned2016-02-09T22:07:09Zen
dc.date.available2016-02-09T22:07:09Zen
dc.date.issued2006-04en
dc.description.abstractThe equivalent T circuit of an induction motor is found in every engineering motors book and is becoming increasingly important with the popularity of vector control. The values used in the circuit are used to dictate the necessary gating signals for the pwm inverter. It is the de facto standard bridge between the field analyst and the motor controller. These parameters are not unique. Force, energy, voltage, and secondary power dissipation can be shown to relate to the product of synchronous reactance and the coupling coefficient of the rotor and stator. The mutual reactance, the secondary inductance, and secondary resistance are non-unique. Yet this surprising feature can be used as a solution integrity check for the field analyst.en
dc.description.departmentCenter for Electromechanicsen
dc.identifierPN_309en
dc.identifierdoi:10.15781/T2S37Wen
dc.identifier.citationK.R. Davey, “The equivalent T circuit of the induction motor: its nonuniqueness and use to the magnetic field analyst,” Twelfth Biennial IEEE Conference on Electromagnetic Field Computation (CEFC 2006), Miami, Florida, USA, April 30-May 3, 2006, p. 175, IEEE Transactions on Magnetics, vol. 43, no. 4, April 2007, pp. 1745-1748.en
dc.identifier.urihttp://hdl.handle.net/2152/33107en
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofCEM Publicationsen
dc.rights.restrictionopenen
dc.subjectRotating Machine EM Launchen
dc.subjectcoupling coefficienten
dc.subjectequivalent circuiten
dc.subjectinductionen
dc.subjectmotoren
dc.titleThe equivalent T circuit of the induction motor: its nonuniqueness and use to the magnetic field analysten
dc.typeconference paperen