Earth pressures applied on drilled shaft retaining walls in expansive clay during cycles of moisture fluctuation

dc.contributor.advisorKlingner, R. E.en
dc.contributor.advisorGilbert, Robert B. (Robert Bruce), 1965-en
dc.creatorKoutrouvelis, Iraklis, 1986-en
dc.date.accessioned2012-10-29T21:28:30Zen
dc.date.available2012-10-29T21:28:30Zen
dc.date.issued2012-05en
dc.date.submittedMay 2012en
dc.date.updated2012-10-29T21:28:49Zen
dc.descriptiontexten
dc.description.abstractEstimating the earth pressures applied on drilled shaft retaining walls in expansive clays is challenging due to the soil's tendency to shrink and swell under cycles of moisture fluctuation. While empirical suggestions do exist, significant uncertainty exists regarding the effect of volumetric changes of the soil on the earth pressures. In order to investigate this uncertainty, a fully instrumented drilled shaft retaining wall named in the honor of Lymon C. Reese, was constructed in the highly expansive clay of the Taylor formation. Inclinometers and optical fiber strain gauges were installed in three instrumented shafts and time domain reflectrometry sensors were placed within the soil to measure changes in the moisture content. Nearly two years of monitoring data have been obtained which are used to estimate the earth pressure distribution at different moisture conditions. Processing of the raw strain data was required to eliminate the effects of tension cracks and other microscale factors that caused significant variation in the results. Good agreement was obtained between the processed strain and inclinometer data as the deflected shapes predicted from both monitoring elements were similar. Finally, the earth pressure distribution for six dates that represent different moisture conditions of the Taylor clay were plotted and the results of the strain gauge and inclinometer analysis were consistent. A p-y analysis was also conducted to estimate the range of earth pressures applied on the wall. A triangular earth pressure diagram was used as external load above the excavation level and the equivalent fluid pressure was evaluated by matching the deflected shapes generated from the inclinometer data to those predicted by the p-y model. The results were compared to the empirical values that TxDOT uses for design of similar type of walls in expansive clay. Finally, the side shear and temperature effects on the lateral response of the wall were quantified. A differential linear thermal model was used to evaluate the temperature effects and a t-z analysis was conducted to account for the side shear applied on the wall due to volumetric changes of the soil. It is recommended that their combined effect be considered in the design.en
dc.description.departmentCivil, Architectural, and Environmental Engineeringen
dc.format.mimetypeapplication/pdfen
dc.identifier.slug2152/ETD-UT-2012-05-5868en
dc.identifier.urihttp://hdl.handle.net/2152/ETD-UT-2012-05-5868en
dc.language.isoengen
dc.subjectExpansive clayen
dc.subjectDrilled shaften
dc.subjectp-y analysisen
dc.subjectt-z analysisen
dc.titleEarth pressures applied on drilled shaft retaining walls in expansive clay during cycles of moisture fluctuationen
dc.type.genrethesisen
thesis.degree.departmentCivil, Architectural, and Environmental Engineeringen
thesis.degree.disciplineCivil Engineeringen
thesis.degree.grantorUniversity of Texas at Austinen
thesis.degree.levelMastersen
thesis.degree.nameMaster of Science in Engineeringen

Access full-text files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
KOUTROUVELIS-THESIS.pdf
Size:
4.54 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.13 KB
Format:
Plain Text
Description: