Show simple item record

dc.creatorDavey, K.R.en
dc.creatorHebner, R.E.en
dc.date.accessioned2015-09-04T16:05:26Zen
dc.date.available2015-09-04T16:05:26Zen
dc.date.issued2006-07en
dc.identifierPR_384en
dc.identifier.citationK.R. Davey and R.E. Hebner, “A new strategy for representation and control of self-contained power systems,” IEEE Transactions on Power Delivery, vol. 21, no. 3, July 2006, pp. 1558-1564.en
dc.identifier.urihttp://hdl.handle.net/2152/30683en
dc.description.abstractPower systems on naval vessels and airplanes are good examples of self-contained power systems. State of the art LEM modules and voltage sensors provide real time current and voltage data. This paper shows how that information can be used to construct dynamic equivalent impedance representations of the system discretized into key trunk lines. Error analysis indicates that the algorithm performing this representation can be updated in one fifth of a cycle if the signal to noise data ratio is 5% or less. The magnitude of the equivalent impedance is sufficient to determine when fault control on either end of the trunk line is required. These same equivalent impedances can be used to determine the best switch configuration to maximize load power while minimizing transmission loss subject to line load capability. The accuracy of the equivalent impedance approach is assessed for transients with active and passive loads.en
dc.language.isoenen
dc.publisherIEEEen
dc.relation.ispartofCEM Publicationsen
dc.subjectGrid Solutionsen
dc.subjectESRDCen
dc.subjectelectric shipen
dc.subjectreconfigurationen
dc.subjectphase analysisen
dc.subjecttransienten
dc.subjectfault detectionen
dc.titleA new strategy for representation and control of self-contained power systemsen
dc.typearticleen
dc.description.departmentCenter for Electromechanicsen
dc.rights.restrictionopenen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record