Browsing by Subject "Coal-fired power plants"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item Carbon dioxide absorption into piperazine promoted potassium carbonate using structured packing(2007-12) Chen, Eric; Rochelle, Gary T.A large-scale pilot plant (0.43 m ID) was extensively modified and converted into an absorber/stripper system to demonstrate CO₂ capture technology using aqueous piperazine promoted potassium carbonate for coalfired power plants. Four pilot plant campaigns were completed. Three campaigns were conducted using 5 m K⁺/2.5 m PZ and 6.4 m K⁺/1.6 m PZ. Flexipac 1Y and Flexipac AQ Style 20 structured packing were used in the absorber. The stripper was tested with 14 sieve trays, IMTP #40 random packing, and Flexipac AQ Style 20 packing. Monoethanolamine (7 m) was tested in the third campaign to establish a base case. An approximate rate analysis showed that 5 m K⁺/2.5 m PZ is two times faster than 7 m MEA and three times faster than 6.4 m K⁺/1.6 m PZ. The location of the temperature bulge moves from the top of the column to bottom as the liquid to gas flow rate ratio is increased. Foaming occurred in the absorber in the first two campaigns and occurred in the stripper in the fourth campaign. Data from the pilot plant was used to develop a K⁺/PZ absorber model in Aspen Plus® RateSep[trademark]. The Hilliard (2005) Aspen Plus® VLE model and the kinetics developed by Cullinane (2005) were incorporated in the model. Data-Fit was simultaneously used to reconcile pilot plant data and perform a regression of the interfacial area and heat loss parameters for the RateSep[trademark] absorber model. The lean loading for the pilot plant data was shifted down by 10% to account for a discrepancy with the Cullinane vapor-liquid equilibrium data. The Data-Fit results showed that the average interfacial area for Flexipac 1Y was 80% of the value measure by the air-water column. The average interfacial area for Flexipac AQ Style 20 for 5 m K⁺/2.5 m PZ was 56% of the air-water measurement. The CO₂ heat of absorption may not have been adequately predicted by the RateSep[trademark] absorber model because the regressed values of heat loss were consistent with forced convection.Item A technical and economic evaluation of CO₂ disposal from coal-fired power plants(2004-08) Sams, Bryan P.; Fisher, W. L. (William Lawrence), 1932-Energy and environmental concerns are often in conflict. However, there are opportunities for technological synergies that can decrease negative environmental impacts while increasing efficiencies in the worldwide quest for traditional energy resources. Increasing concentrations of anthropogenic CO₂ and other greenhouse gasses in the Earth's atmosphere are contributing to the natural greenhouse gas effect, possibly leading to changes in the Earth's climate. Meanwhile, the development of commercial CO₂ capture technologies, in concert with already-developed enhanced oil recovery methods, has tremendous potential to increase incremental oil production and limit the negative impacts of coal fired power generation. Capturing CO₂ from the flue gas and then disposing of it in mature oil reservoirs can achieve a significant reduction of greenhouse gases while providing an economic incentive to develop geologic sequestration that does not exist in the United States under current environmental regulations. This research describes geologic sequestration technologies and principles of economic feasibility. Ultimately, the retrofit and disposal process described throughout the text is not economic